Please choose the option that has the highest thermal conductivity.
In Zone 6, the minimum required RSI insulation value for above ground exterior walls (2”x6”@16”) in a SFD without a HRV is ______.
Code Reference:
Table 9.36.2.6.-A
Effective Thermal Resistance of Above-ground Opaque Assemblies in Buildings without a Heat-Recovery Ventilator
Forming Part of Sentence 9.36.2.6.(1)
Above-ground Opaque Building Assembly | Healing Degree-Days of Building Location,(1) in Celsius Degree- Days | |||||
---|---|---|---|---|---|---|
Zone 4 <3000 |
Zone 5 3000 to 3999 |
Zone 6 4000 to 4999 |
Zone 7A 5000 to 5999 |
Zone 7B 6000 to 6999 |
Zone 8 ≥ 7000 |
|
Minimum Effective Thermal Resistance (RSI), (m2-K)/W | ||||||
Ceiling below attics | 6.91 | 8.67 | 8.67 | 10.43 | 10.43 | 10.43 |
Cathedral ceilings and flat roofs | 4.67 | 4.67 | 4.67 | 5.02 | 5.02 | 5.02 |
Walls (2) | 2.78 | 3.08 | 3.08 | 3.08 | 3.85 | 3.85 |
Floors over unheated spaces | 4.67 | 4.67 | 4.67 | 5.02 | 5.02 | 5.02 |
In what circumstances is the court likely to award payment to a subcontractor on the terms of “Quantum Meruit”.
If you have any questions, call us at 778-846-7899, email us at [email protected] or fill out the form below.
Quick Pass Master is an exam prep school that helps students pass BC Real Estate Licensing exams. Our courses produced thousands of success stories in the real estate industry, including many highly ranked real estate agents in Vancouver. With hundreds of five star reviews, and years of experience, Quick Pass Master is the top choice for you.